London

Facility and Security

  • Raised Flooring: 5,000 sq m
  • 15 MVA Total Utility Power
  • Manned 24x7x365
  • Biometric Scanners
  • Video Surveillance
  • Alarm System
  • Key Card Access Required
  • Laser-Based Smoke Detection

Power and Cooling

  • 250 kW UPS Power Capacity
  • N+1 Redundancy
  • Diesel-Powered Generators with 2MW Capacity each
  • 10,000 Litre Fuel Tanks
  • Over 3,000 Tons of Cooling Capacity, N+3 Redundancy
  • Double Interlocked Dry Pipe Pre-Action Sprinkler System

Connectivity and Infrastructure

  • Multiple Tier-1 Service Providers
  • 10-Gigabit Ethernet Per Carrier
  • Redundant Cisco 3-Tier LAN Architecture
  • 8 Carriers Providing Fiber-Based Connectivity to Site
  • Redundant Cisco & ARISTA Routers
  • BGP Multipath Route Optimization
  • Cisco Switches for Aggregation, Distribution & Access Layer

Standards and Compliance

  • SSAE18 SOC1, SOC2, SOC3
  • PCI DSS
  • ISO27001
  • ISO14001
  • ISO9001

 

Frankfurt

Facility and Security

  • Raised Flooring: 283 sq m
  • 12.2 MVA Total Utility Power
  • Manned 24x7x365
  • Biometric Scanners
  • Video Surveillance
  • Alarm System
  • Key Card Access Required
  • Laser-Based Smoke Detection

Power and Cooling

  • •240 kW UPS Power Capacity
  • 2N Redundancy
  • Diesel-Powered Generators w/ 2,500 kVA Capacity each
  • 45,071 Litres of Fuel on Site
  • 1.23 Tons of Cooling Capacity, N+1 Redundancy
  • Double Interlocked Dry Pipe Pre-Action Sprinkler System

Connectivity and Redundancy

  • Multiple Tier-1 Service Providers
  • 10-Gigabit Ethernet Per Carrier
  • Redundant Cisco 3-Tier LAN Architecture
  • 2 CarriersProviding Fiber-Based Connectivity to Site
  • Redundant Cisco & ARISTA Routers
  • BGP Multipath Route Optimization
  • Cisco Switches for Aggregation, Distribution & Access Layer

Standards and Compliance

  • SSAE18 SOC1, SOC2, SOC3
  • PCI DSS
  • ISO27001
  • ISO14001
  • ISO9001

 

Dallas

Facility and Security

  • Raised Flooring: 56,179 sq ft
  • 14 MW Total Utility Power
  • Manned 24x7x365
  • Biometric Scanners
  • Video Surveillance
  • Alarm System
  • Key Card Access Required
  • Laser-Based Smoke Detection

Power and Cooling

  • 6.975 MW UPS Power Capacity
  • N+1 Redundancy
  • Diesel-Powered Generators w/ 2,000 kW Capacity each
  • 8 x 4,000 Gallon Fuel Tanks
  • Over 3,150 Tons of Cooling Capacity, N+3 Redundancy
  • Double Interlocked Dry Pipe Pre-Action Sprinkler System

Connectivity and Infrastructure

  • Multiple Tier-1 Service Providers
  • 10-Gigabit Ethernet Per Carrier
  • Redundant Cisco 3-Tier LAN Architecture
  • 4 Carriers Providing Fiber-Based Connectivity to Site
  • Redundant Cisco & ARISTA Routers
  • BGP Multipath Route Optimization
  • Cisco Switches for Aggregation, Distribution & Access Layer

Standards and Compliance

  • SSAE18 SOC1, SOC2, SOC3
  • PCI DSS
  • ISO27001
  • ISO14001
  • ISO9001

Chicago

Facility and Security

  • Raised Flooring: 70,843 sq ft
  • 56 MW Total Utility Power
  • Manned 24x7x365
  • Biometric Scanners
  • Video Surveillance
  • Alarm System
  • Key Card Access Required
  • Laser-Based Smoke Detection

Power and Cooling

  • 10.2 MW UPS Power Capacity
  • N+2 Redundancy
  • Diesel-Powered Generators w/ 2,250 KW Capacity each
  • 50,000 Gallon Fuel Tanks
  • Over 18,400 Tons of Cooling Capacity, N+2 Redundancy
  • Double Interlocked Dry Pipe Pre-Action Sprinkler System

Connectivity and Infrastructure

  • Multiple Tier-1 Service Providers
  • 10-Gigabit Ethernet Per Carrier
  • Redundant Cisco 3-Tier LAN Architecture
  • 14 CarriersProviding Fiber-Based Connectivity to Site
  • Redundant Cisco & ARISTA Routers
  • BGP Multipath Route Optimization
  • Cisco Switches for Aggregation, Distribution & Access Layer

Standards and Compliance

  • SSAE18 SOC1, SOC2, SOC3
  • PCI DSS
  • ISO27001
  • ISO14001
  • ISO9001

Singapore

Facility and Security

  • Raised Flooring: 8,475 sq m
  • 24 MW Total Utility Power
  • Manned 24x7x365
  • Biometric Scanners
  • Video Surveillance
  • Alarm System
  • Key Card Access Required
  • Laser-Based Smoke Detection

Power and Cooling

  • 12 MW UPS Power Capacity
  • 2N Redundancy
  • 12 Diesel-Powered Generators w/ 2,000 kVA Capacity each
  • Full Loading Runtime (36 hours)
  • Over 5,714 Tons of Cooling Capacity, N+1 Redundancy
  • Double Interlocked Dry Pipe Pre-Action Sprinkler System

Accessibility and Redundancy

  • Multiple Tier-1 Service Providers
  • 10-Gigabit Ethernet Per Carrier
  • Redundant Cisco 3-Tier LAN Architecture
  • 6 CarriersProviding Fiber-Based Connectivity to Site
  • Redundant Cisco & ARISTA Routers
  • BGP Multipath Route Optimization
  • Cisco Switches for Aggregation, Distribution & Access Layer

Standards and Compliance

  • SSAE18 SOC1, SOC2, SOC3
  • PCI DSS
  • ISO27001
  • ISO14001
  • ISO9001